• Static Voltage Regulator

    Datadigital-SVR is with no moving parts in the static voltage regulator. Voltage regulation is performed entirely by microcontroller-controlled digital technology for milliseconds. There are no parts that are worn out and old in time.

    More
  • AC Motor Driver

    AC motor drives are the modern, speed control machines which work with the IPM-SPWM technique that adjust the speed of 3 Phase The alternating current from zero to the desired value with high starting torque.

    More
  • Uninterruptible Power supply

    Uninterrupted power supplies are a solution to systems that are connected to the outputs, called critical loads, which are not intended to be affected by power interruptions, and which must be supplied with very regular voltage and frequency.

    More
Uninterruptible Power Suplies
 

 

3Phase / 3Phase On-Line UPS

DS|POWER H UPS SERİES

30kVA - 400kVA

General Specifications

• Transformerless UPS technology
• 3 Level topology
• Low current harmonic distortion in input
• High input power factor
• High efficiency up to 95%
• Cold start feature
• Static and maintenance bypass switch
• Output short-circuit and overload protection
• External REPO input
• 512 event recording (512 events, 45000 alarms)
• Time and calendar
• Automatic battery test, remaining battery time indication
• Heat compensated charging system
• 2 RS232 serial ports and 12 dry contact outputs
• Modular structure controlled by 3 DSPs
• Optional SNMP and MODBUS adapters
• Optional graphic panel
• Optional usb memory
• 2 Year warranty
• 10 year spare parts support
• Manufactured according to EC EN62040 directive
• Fully digital structure
• Small footprint
• Eco mode operation (optional)
• Less electronic components
• Output current limitation
• Advanced control at entrance
• Selectable input / output voltage / frequency range
• Split by-pass input (second input)
• Output DC leakage protection
• Separate DSP for inverter control
• Separate DSP for PFC
• 3-level battery protection
• High charge current capacity
• Charge / discharge current indication
• Advanced remote control features

Technical Specifications

Power

(kVA)

 
30
40
60
80
100
INPUT Voltage Range

380/400 VAC 3F + N + T ± %20 (%100 load)/-%40 (%70 load)

Frequency Range
50Hz. / 60Hz. ± %5
OUTPUT Voltage

380/400 VAC 3F + N ,± %1 (optional 415 VAC )

Frequency

50 / 60 Hz

THDv

< %3 ( %100 Lineer load)

Peak Coefficient
(Crest Factor) 3:1
GENERAL Technology
Online-double conversion, PFC
Control Microprocessor, SPWM
Haberleşme SNMP(optional), RS232

Remote

Monitoring

SNMP manager and web browser power management
Software

 

T-Mon Admin Multi UPS monitoring 10-50-100-200 user , T-Mon Server 50-100-200 user

AMBIANCE

Relative humidity
% 0-95 (without condensation)
Height
2000 m

Noise

< 45 dB (A)
UPS
CABINED

Dimensions

(GxDxY) (mm)

400x815x

1040

515x855x1440

BATTERY

İnternal Battery

Number

2x30 (±30) : 60 pieces
Battery Type
Dry type without maintenance
 

Power

(kVA)

 
160
200
250
300
400
INPUT Voltage Range

380/400 VAC 3F + N + T ± %20 (%100 load)/-%40 (%70 load)

Frequency Range
50Hz. / 60Hz. ± %5
OUTPUT Voltage

380/400 VAC 3F + N ,± %1 (optional 415 VAC )

Frequency

50 / 60 Hz

THDv

< %3 ( %100 lineer load)

Peak Coefficient
(Crest Factor) 3:1
GENERAL Technology
Online-double conversion, PFC
Control Microprocessor, SPWM
Communication SNMP(optional), RS232

Remote

Monitoring

SNMP manager and web browser power management
Software

 

T-Mon Admin Multi UPS monitoring 10-50-100-200 user , T-Mon Server 50-100-200 user

AMBIANCE

Relative Humidity
% 0-95 ( without condensation)
Height
2000 m

Noise

< 45 dB (A)
UPS
CABINED

Dimensions

(GxDxY) (mm)

515x855x

1440

880x775x1900

1250x775x

1900

BATTERY

İnternal Battery

Number

2x30 (±30) : 60 pieces
Battery Type
Dry Type without Maintenance

 

 

Katalog|(PDF)